Best smoke detector for attic.
During the rebuild i asked for smoke detectors in the attic but was told they would go off all the time due to particulate issues up there etc.
This hardwired alarm includes a 9v battery backup in case of a power outage and it can be used as a standalone unit or part of an interconnected system.
Install the first attic smoke detector on the wall near the stairs anywhere between the 4 inch and 12 inch marks.
Best sellers rank 1 396 210 in tools home improvement see top 100 in tools home improvement 1 288 in smoke detectors fire alarms.
Beyond our best overall pick one of the best dual sensor smoke detectors out there is the kidde hardwire smoke detector with ionization photoelectric dual sensors.
When one smoke alarm sounds they all sound.
The us fire administration fema recommends that you have a heat detector rather than a smoke alarm in your garage.
5 measure and mark a distance of 4 inches on the ceiling from each wall.
Paint stickers or other decorations could keep the alarms from working.
Another location in a home where you should have a heat detector rather than a smoke alarm is the attic.
For the best protection interconnect all smoke alarms.
A smoke detector will pick up a neighbor s burn barrel smoke products of combustion but a heat detector operates on the rate of rise principle.
Never paint smoke alarms.
The kidde firex hd135f is a 120 volt ac the kidde firex hd135f is a 120 volt ac wire in heat alarm that responds to temperature rather than smoke.
Don t install smoke alarms near windows doors or ducts where drafts might interfere with their operation.
The kidde hd135 f is inter connectable.
That is to say when the attic gets hot quickly not just from a hot summer day then it will go into alarm.
Smoke alarms are not designed for garages and attics and are much more likely to fail than a heat detector.
This is the best type of smoke detector to purchase as it provides the most complete level of protection against all types of fires.
Like smoke detectors co alarms need to be tested regularly and cleaned as indicated in the manufacturer s use and care booklet.
The alarm will sound if temperatures rise above 135 f.
Is discontinued by manufacturer no date first available october 3 2011 manufacturer walter kidde.
If the unit operates off a battery test the detector weekly and replace the battery at least once a year.
This won t work as i also had attic fans installed as part of the.